Published by Sudan Heart Society • Double-Blind Peer Review
Background AF is the most common arrhythmia in clinical practice, especially in elderly patients. The clinical presentation and detection of AF is challenging in patients with CIEDs. Regular screening for AHRE during routine interrogation CIEDs is of great importance. Objectives: To study the prevalence of AF and AHRE in patients with implanted dual chamber pacemakers and the risk of thromboembolism and bleeding from anticoagulation. Methods: All adult patients with DDD pacemaker who presented to the pacemaker clinic for pacemaker interrogation in Al Shaab Teaching Hospital and Sudan Heart Center from March 2016 to September 2016 were screened for AF using baseline ECG , interrogation for AHRE and analysis of EGM when available. Result: A total 56 patients were included, most of them above 65 years and M:F was 1:1. One patient had permanent AF. AHRE was detected in 18 patients with only 3 patients with device EGM confirming AF . Symptoms were detected in 33% patients. 54 The mean CHADS2-VASc was 2.7 (+/- 1.8) and the mean HAS-BLED score was 1.7(+/- 1.3). Conclusion: AF and AHRE detected using surface ECG, EGM or AHRE algorithm is common in our study population with the significant risk of thromboembolism with low risk of bleeding from anticoagulation.
AHRE which are present in 10-15% of patients with pacemakers (4). AF is the commonest AHRE are associated with prevalence arrhythmia detected in man with a of frank AF and thromboembolic huge burden of disease worldwide (1).
complications, though less than It is associated with significant patients with established AF and not morbidity and mortality from stroke all AHREs are AF (5). Two ongoing and heart failure as well as impaired quality of life (2)(3).
trials may provide definitive evidence on the benefit of oral anticoagulation Patients with CIEDs represent a in patients with AHRE; Apixaban for great opportunity to screen for AF the Reduction of Thrombo-Embolism during interrogation. Presence of in Patients With Device-Detected atrial leads will allow to detect Sub-Clinical Atrial Fibrillation (ARTESiA) and Non vitamin K antagonist Oral anticoagulants in patients with Atrial High rate episodes (NOAH – AFNET )(6,7).
To study frequency of established atrial fibrillation and AHRE in patients as well as risk of thromboembolism and bleeding from anticoagulation in a sample of Sudanese patients with dual chamber pacemaker.
This is a hospital based crosssectional prospective and retrospective study conducted from March 2016 to September 2016. All patients with DDD PPM at Al Shaab
Teaching hospital and Sudan Heart Center pacemaker clinics , both located in Khartoum, Sudan were included. Patients younger than 16 years or do not consent to the procedure were excluded.
Patients records and baseline ECGs were reviewed. PPM interrogation for AHRE, defined as atrial rates > 180 bpm and lasting > 5 min , as adopted by European Society Cardiology 2016 guidelines for Atrial fibrillation , was performed. Risk for thromboembolism and bleeding risk was assessed using CHADS2vasc score and HASBLED score respectively(8).
Data was computerized and analyzed using statistical package of social sciences (SPSS version 21). Ethical approval was obtained from Sudanese Medical Specialization Board (SMSB), Al Shaab Teaching Hospital and Sudan Heart Center .
A total of 56 patients with dual chamber pacemakers were included in the study with a mean of duration 42.6 months since implantation. Age distribution is shown in figure 1 and the male to female ratio was 1:1.
45
40
35
30
25 46.4 20
15 25 10 12.5 5 7.1 5.4 3.6 0 16-25 26-35 36-45 46-55 56-65 ≥ 65
The indications for PPM implantation were high grade block in 89% of patients and sick sinus node in 11%.
The total number of patients who have AF or AHRE analyzed by all methods was 19 (33.9%) . One patient (1.7%) developed permanent AF , confirmed on resting ECG, and pacing mode was switched to VVI. The total number of patients who developed AHRE ( ≥ 180 bpm, > 5min) during interrogation were 18 (32.1%). Atrial episodes of < 180 bpm or < 5 min were detected in 8(14.2%), patients and 29 (51.7%) had no episodes detected. Figure (2) shows distribution of atrial episodes in study cohort.
n=56
[VALUE]1(1.7%)
18(32.1%)
29(51.7%)
8(14.2%)
AHRE Non AHRE atrial epidoses No atrial episodes Permanent AF
Only 3 (5.4%) had available EGM during episodes and met criteria for AF. During interrogation, the median number of episodes of AHRE was 533.4+/- 1729.90 .
Only 33% of patients developed symptoms. Fig (-) shows distribution of symptoms n=18
4 (22%)
7(33%)
3(17%)
4(22%)
Syncope Shortness of breath Shortness of br + syncope Palpitations
The mean CHADS2-VASc score for patients with AHRE was 2.7 +/-1.81 and the mean HAS-BLED score was 1.7+/- 1.34.
The study was conducted in two large cardiac centers in the capital Khartoum with experienced staff in device implantation and interrogation.
In our study most of the patients were above 65 years and the commonest indication was high grade block and this similar to other published data in low and middle income countries (9).
Only a minority of our study sample with AHRE developed symptoms , the commonest being syncope, and this is similar to a study done by Quirino et al in Italy and showed only 20% of their sample are symptomatic (10) In our study 32.1% developed significant AHRE which is higher than reported literature of 10-15 % and only 3 patients with AHRE had EGMs recorded by their device and this is similar to published data (4). Still most are asymptomatic and hence the importance of routine follow-up for such episodes.
As per ESC 2016 guidelines for AF, patients with AHRE ( > 180 bpm , > 5-6 min) should have AF verified by resting ECG , device EGM or other rhythm monitoring devices as well as risk for stroke assessed using CHADs-VASc score (6). Our patients had only resting ECG done for AF detection.
An average CHADS2-VASc score of 2.7+/-1.8 makes our study population at significant risk for thromboembolic complications. This is similar to data by Arce et al and Gonzalez et al (11,12). At the same time bleeding risk from oral anticoagulants in our study sample seems to be low with an average HAS- BLED of 1.7+/-1.34.
AF detected using surface ECG, EGM or suspected due to AHRE algorithm is common in our study population with significant risk of thromboembolism and low risk of bleeding from anticoagulation.
Limitations EGMs or long-term rhythm monitoring.
The main limitations of our study is inability to definitively verify af in