Buddy Wire Technique In Percutanous Coronary Intervention
Elbagir Elbasheer, Isam Eltayeb, Mubarak Hassan, Shazally Musa
A 70 Year old male presented with acute inferior myocardial infarction and complete heart block. The still images are from his procedure.
Image 1 Image 2
Image 1 shows the totally occluded RCA with a temporary pacing wire to the RV apex. After multiple inflations with different size balloons it was not possible to cross the lesion with 2.5X22 mm stent. A Buddy wire is passed to the distal RCA(Image2). Stent passed successfully through the lesion and the buddy wire was removed immediately ( make sure to remove the right wire!). Stent inflated(Image3) with and excellent final angiographic result and TIMI iii flow( Image 4).
Image 3 Image4
Discussion
The Buddy wire technique is a simple trick which renders an otherwise difficult procedure into a simple peace of cake one. It spares time and effort and saves the operator the haste of replacing the whole hardware system and/or further traumatic balloon dilatation. The Buddy wire is meant to support the guiding catheter, further straighten the vessel and facilitate passage of the balloon/stent thorough the calcified and fibrotic lesions.