<?xml version="1.0" encoding="UTF-8"?>
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="case_report" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">shj</journal-id>
      <journal-title-group>
        <journal-title>Sudan Heart Journal</journal-title>
        <abbrev-journal-title abbrev-type="publisher">SHJ</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="epub">1858-6791</issn>
      <issn pub-type="ppub">1858-6783</issn>
      <publisher>
        <publisher-name>Sudan Heart Society</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">78</article-id>
      <article-id pub-id-type="doi">10.25239/SHJ/Vol5/No1/casereport</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Case Report</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Successful Primary Percutaneous Coronary Intervention During Cardiac Arrest Utilizing an Automated Chest Compression Device</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes">
          <name>
            <surname>Mohammed</surname>
            <given-names>Sahar H.</given-names>
          </name>
          <aff>Department of Cardiology, Almana General Hospital, Dammam, Saudi Arabia</aff>
          <email>sahar-h-mohammed@noreply.sudanheartjournal.com</email>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Eltayeb</surname>
            <given-names>Safa M. H.</given-names>
          </name>
          <aff>Department of Cardiology, Almana General Hospital, Dammam, Saudi Arabia</aff>
          <email>safatayeb@yahoo.com</email>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Eltayeb</surname>
            <given-names>Abdalla Osman</given-names>
          </name>
          <aff>Department of Cardiology, Almana General Hospital, Dammam, Saudi Arabia</aff>
          <email>abdalla-osman-eltayeb@noreply.sudanheartjournal.com</email>
        </contrib>
      </contrib-group>
      <pub-date pub-type="epub">
        <year>2017</year>
      </pub-date>
      <volume>5</volume>
      <issue>1</issue>
      <abstract>
        <p>The overall prognosis of Out-of-Hospital cardiac arrest is poor; when combined with ventricular fibrillation and ST Elevation Myocardial Infarction (STEMI) the overall prognosis is extremely poor. Effective Cardiopulmonary Resuscitation (CPR) is essential in achieving Return of Spontaneous Circulation (ROSC). However, manual chest compression remains a drawback due to variability in compression quality. It, also, acts as an obstacle to performing primary percutaneous coronary intervention (PPCI) in patients with STEMI. This report presents a case of Ventricular Fibrillation (VF) &amp; Pulseless Electrical Activity (PEA) treated with PPCI facilitated by the use of an automated chest compression device.</p>
      </abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Primary Percutaneous Coronary Intervention</kwd>
        <kwd>Out-of-Hospital Cardiac Arrest (OHCA)</kwd>
        <kwd>Automatic Chest Compression Device</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec>
      <title>Article Full Text</title>
      <p>Introduction</p>
      <p>Cardiac arrest is a major public health problem, with more than 350,000 patients being treated for Out-of-Hospital Cardiac Arrest (OHCA) by the emergency medical services in the United States each year, of which only 9.8% survive to hospital discharge(1).</p>
      <p>Effective chest compressions are one of the fundamental elements of successful cardiopulmonary resuscitation. Achieving a coronary perfusion pressure of more than 15 mmHg increases the possibility of obtaining return of spontaneous circulation (ROSC) following defibrillation. However, there are several drawbacks to performing manual chest compressions: inter- and intra-rescuer variability of compression quality, the repetitive interruptions for defibrillation and rescuer fatigue; leading to inadequate manual chest compression (2).The guidelines recommend changing the rescuer every two minutes (3), which often results in interruption of chest compressions which may adversely impact ROSC and neurological recovery.</p>
      <p>In the past few years, different devices for automated chest compression or chest compression-decompression have been introduced. The LUCAS™ (Jolife AB/Physio-Control, Lund, Sweden) chest compression system and the Autopulse®Resuscitation System (Zoll, Chelmsford, MA) are currently in use. The LUCAS™device (Jolife AB/Physio-Control, Lund, Sweden) is a mechanical device that delivers sternal compression and decompression at a rate of around 100 per minute and a depth of around 4–5 cm by using a piston with a suction cup. Most of the parts in the LUCAS™(Jolife AB/Physio- Control, Lund, Sweden) devices are S Mohammed et al, Successful Primary Percutaneous … http://dx.doi.org/10.25239/SHJ/Vol5/No1/casereport</p>
      <p>radiolucent. The first LUCAS-1™(Jolife myocardial infarction (STEMI). He required AB/Physio-Control, Lund, Sweden)) device high dose of inotropes (Dobutamine and was gas-driven, whereas the newer version, Dopamine both at 20 microgram/kg/min) to LUCAS-2™((Jolife AB/Physio-Control, maintain a blood pressure above 80/40; he Lund, Sweden) is electrically driven.</p>
      <p>was taken emergently to the Cardiac These devices have been proven to be as Catheterization Lab (CCL) for Primary effective as manual CPR. An autopsy study Percutaneous Coronary Intervention (PPCI) has shown that injuries after after securing his airway.</p>
      <p>LUCAS™cardiopulmonary resuscitation (CPR) are comparable to those seen after On arrival in the CCL, he had a further VF manual CPR (4). However, animal studies Arrest, CPR was initiated and a further shock have shown that the device resulted in higher was delivered with developed of Pulseless cerebral blood flow and cardiac output (5), Electrical Activity (PEA). The Autopulse® and higher coronary perfusion and fewer rib fractures (6) when compared to manual Resuscitation System (Zoll, Chelmsford, CPR. On the other hand, a recent MA) was placed to provide CPR during randomized clinical trial comparing PPCI achieving a BP of more than 120/80 mechanical CPR and manual CPR did not mmHg. Femoral Access was established result in improved 4-hour survival using a 6F sheath, EBU 3.5 guiding catheter (7).Hence, the use of mechanical (Medtronic, Dublin, Ireland) was used to resuscitation devices has not been introduced engage the left coronary artery. Angiography into the European Resuscitation Guidelines revealed proximal total occlusion of Left (3).</p>
      <p>Anterior Descending artery (Photo 1). A In this report, we present the case of a patient BMW wire (Abbott, Lake Bluff, IL, USA) who survived OHCA in the context of was used to cross the lesion, and the lesion STEMI; PPCI was successfully performed was dilated using a 2.0X 10mm compliant with short door to balloon time, utilizing the balloon and stented by a 3.0X 26mm drug Autopulse® Resuscitation System (Zoll, Integrity® Chelmsford, MA) throughout the procedure.</p>
      <p>eluting stent (Resolute , Medtronic, Dublin, Ireland) at 16 atmospheres. Following PCI (Photo 2), the</p>
      <p>Case Report</p>
      <p>patient regained his pulse and blood pressure A previously healthy 48-year-old male, of 90/70, the machine was switched off and smoker, with family history of premature inotropes were weaned gradually during the ischemic heart disease, developed chest pain rest of the procedure.</p>
      <p>while at work. A few minutes before reaching the hospital, he became unresponsive, chest compression was started by his colleagues; the initial rhythm in the Emergency Room was ventricular fibrillation (VF), with successful defibrillation. He developed recurrent VF requiring resuscitation and intravenous amiodarone, Electrocardiogram (ECG) post resuscitation showed anteroseptal ST segment elevation S Mohammed et al, Successful Primary Percutaneous … http://dx.doi.org/10.25239/SHJ/Vol5/No1/casereport</p>
      <p>placement of a temporary pacing wire via the right femoral vein and an intra-aortic balloon pump (IABP) was placed through the same femoral access site, and 1:1 diastolic augmentation was started. The Patient’s heart rate and blood pressure improved and was stable on transfer to the Cardiac Care Unit (CCU) safely with lower doses of inotropes (Dopamine 5 and Dobutamine 7.5 microgram/Kg/min respectively).</p>
      <p>Echocardiography was done which revealed mild anteroseptal wall hypokinesis with an ejection fraction of 47%. The patient developed ventilator associated pneumonia, but eventually made a good recovery, weaned of the ventilator, and discharged Photo 1. Coronary angiography revealing home in good condition. There was no rib proximal LAD occlusion fracture or any other complications related to the device.</p>
      <p>The door to balloon time was 44 minutes despite his recurrent cardiac arrests. It took 14 minutes from femoral artery puncture to first balloon inflation and 4 minutes from first coronary contrast injection to balloon inflation and 26 minutes to the last coronary contrast injection. It took about 41 minutes for the whole procedure including the temporary wire and IABP.</p>
      <p>Discussion</p>
      <p>In this case of OHCA and anteroseptal STEMI, the use of an automated chest compression device allowed the definitive management of the reversible cause of cardiac arrest while the patient was still in cardiopulmonary arrest which would have Photo 2. Stented LAD been impossible when doing conventional Coronary Angiography of the Right CPR.</p>
      <p>Coronary Artery (RCA) and Left Circumflex A number of case reports have been artery (LCX) revealed normal vessels.</p>
      <p>published outlining the advantages of the Finally, the patient developed brief automated chest compression device during bradyarrhythmia, post PCI requiring the PCI. Libungan et al, used the LUCAS™ S Mohammed et al, Successful Primary Percutaneous … http://dx.doi.org/10.25239/SHJ/Vol5/No1/casereport</p>
      <p>device (Jolife AB/Physio-Control, Lund, in the CCL for patients undergoing PCI and Sweden) and PPCI was successfully pericardiocentesis(10). We believe the use of performed in the RCA after refractory VF automated chest compression devices can with a good neurological outcome(8). Ali et save lives of patients in refractory VF due to al, reported the first case of successful PPCI acute myocardial infarction as it allows during ongoing VF and mechanical CPR in a simultaneous PCI and effective CPR.</p>
      <p>patient with OHCA and STEMI(9). This is Most of reported cases in the literature were the first reported case, to the best of our done using LUCAS™ device (Jolife knowledge, for using the Autopulse® AB/Physio-Control, Lund, Sweden). When Resuscitation System (Zoll, Chelmsford, compared with AutoPulse® Resuscitation MA) during PPCI during cardiac arrest with System (Zoll, Chelmsford, MA), LUCAS™ a short door to balloon time. It is common (Jolife AB/Physio-Control, Lund, Sweden) practice to believe that PPCI cannot be done device parts were more translucent resulting during CPR, resulting in delaying the in better visualization. We managed to procedure till the patient is hemodynamically overcome this, by using straight oblique stable which is sometimes impossible as in projections only, and a good outcome was this case unless the underlying cause of the achieved in spite of that limitation.</p>
      <p>cardiac arrest is addressed. Without the automated chest compression device, PPCI</p>
      <p>Conclusion</p>
      <p>would not have been safely performed, and This case proves that PPCI during CPR in death would have been the likely outcome.</p>
      <p>patients with refractory VF can be During conventional CPR, using manual successfully performed using Autopulse® compressions, it is difficult to proceed with Resuscitation System (Zoll, Chelmsford, PCI as the rescuer is exposed to a large MA). In spite of limited views, PPCI was radiation dose; performing effective CPR successful and the patient had a good clinical while wearing radiation protective gear is outcome. This experience encourages physically challenging. Furthermore, the physicians to consider using this device in rescuer obstructs the motion of the X-ray patients with refractory VF or PEA during source and image intensifier. Moreover, in elective or emergency PCI despite its’ such patients with refractory VF, the rescuer associated limitations.</p>
      <p>can get fatigued quickly, diminishing the quality of CPR and reducing the patient’s</p>
      <p>Acknowledgements</p>
      <p>chances of survival. The use of mechanical I, Dr Abdalla Eltayeb, on behalf of other chest compression device ensures that the authors certify that the manuscript is patient is getting effective, reliable CPR, original. I undertake full responsibility for creates no barriers to the motion of the X-ray any ethical issue of medical activity or source and allows PPCI to proceed without practice described in the manuscript.</p>
      <p>interruption. It maintains satisfactory blood Financial Disclosure flow to the brain and increases the likelihood The authors have no financial disclosures relevant to this publication.</p>
      <p>of a good neurologic outcome.</p>
      <p>Wagner et al, described relatively favorable outcomes with the use of mechanical chest compression device in lengthy cardiac arrests S Mohammed et al, Successful Primary Percutaneous … http://dx.doi.org/10.25239/SHJ/Vol5/No1/casereport</p>
      <p>References</p>
      <p>Go AS MD, Roger VL, Benjamin EJ, Berry 6.</p>
      <p>Liao Q ST, Paskevicius A, Wohlfart B, Steen JD, Borden WB, Bravata DM, Dai S, Ford ES, Fox S. Manual versus mechanical cardiopulmonary CS, Franco S, Fullerton HJ, Gillespie C, Hailpern SM, resuscitation. An experimental study in pigs. BMC Heit JA, Howard VJ, Huffman MD, Kissela BM, Cardiovasc Disord. 2010;10(53).</p>
      <p>Kittner SJ, Lackland DT, Lichtman JH, Lisabeth LD, 7.</p>
      <p>Rubertsson S LE, Smekal D, Östlund O, Magid D, Marcus GM, Marelli A, Matchar DB, Silfverstolpe J, Lichtveld RA, Boomars R, Ahlstedt B, McGuire DK, Mohler ER, Moy CS, Mussolino ME, Skoog G, Kastberg R, Halliwell D, Box M, Herlitz J, Nichol G, Paynter NP, Schreiner PJ, Sorlie PD, Stein Karlsten R. Mechanical chest compressions and J, Turan TN, Virani SS, Wong ND, Woo D, Turner simultaneous defibrillation vs conventional MB; American Heart Association Statistics cardiopulmonary resuscitation in out-of-hospital Committee and Stroke Statistics Subcommittee. Heart cardiac arrest: the LINC randomized trial. JAMA : the disease and stroke statistics--2013 update: a report journal of the American Medical Association.</p>
      <p>from the American Heart Association. Circulation.</p>
      <p>2014;211(1):53-61.</p>
      <p>2013;127(1):e6-e245.</p>
      <p>Libungan B DC, Omerovic E. Successful 2.</p>
      <p>Hightower D TS, Stone CK, Dunn K, March percutaneous coronary intervention during cardiac JA. Decay in quality of closed-chest compressions arrest with use of an automated chest compression over time. Ann Emerg Med. 1995;26(3):300-3.</p>
      <p>device: a case report. Ther Clin Risk Manag.</p>
      <p>Koster RW BM, Bossaert LL, Caballero A, 2014(10):255-7.</p>
      <p>Cassan P, Castrén M, Granja C,, Handley AJ MK, 9.</p>
      <p>Ali A HS, Cox D. Coronary intervention on a Perkins GD, Raffay V, Sandroni C. European moving target: a case report and procedural Resuscitation Council Guidelines for Resuscitation considerations. J Invasive Cardiol. 2013;25(8):E178- 2010 Section 2. Adult basic life support and use of 9.</p>
      <p>automated external defibrillators. Resuscitation.</p>
      <p>Wagner H TC, Friberg H, Harnek J, Kern K, 2010;10(127-92):1277-92.</p>
      <p>Lassen JF, Olivecrona GK. Cardiac arrest in the 4.</p>
      <p>Smekal D JJ, Huzevka T, Rubertsson S. No catheterisation laboratory: a 5-year experience of difference in autopsy detected injuries in cardiac using mechanical chest compressions to facilitate PCI arrest patients treated with manual chest compressions during prolonged resuscitation efforts. Resuscitation. compared with mechanical compressions with the 2010;81(4):383-7.</p>
      <p>LUCAS device--a pilot study. Resuscitation.</p>
      <p>2009;80(10):1104-7.</p>
      <p>Rubertsson S KR. Increased cortical cerebral blood flow with LUCAS; a new device for mechanical chest compressions compared to standard external compressions during experimental cardiopulmonary resuscitation. Resuscitation.</p>
      <p>2005;65(3):357-63.</p>